OmniLog Flow Total Reports


Flow Total Reports is a plug in report to be used with the Omnilog Data Management Program.

The function of the Flow Total Reports is to calculate the Total Volume per Hour, Day, Week and Month from flow data. Flow data can be in any units as long as the flow time period is per second, per minute or per hour. This report is to be used when flow is measured with an analog input of a GP-HR or SafeT data logger. This will typically be on a 4-20mA input. If the digital pulse input of the GP-HR is used, Total Volume will be automatically available in the Statistics and Period reports.

The Flow Total Reports are installed by copying the file omnireportflow.exe into the same folder as the main Omnilog program. This will typically be
C:\Program Files\OMNI\

The Flow Total Report will be added as an additional report option in the Omnilog Data Management Program. It can be accessed from the Report option of the View menu and from the Report icon on the toolbar.

The dataset to be used for the report should be selected before the Flow Total Report is selected. If you are using "Connected Logger" as the current dataset, make sure you have downloaded data before selecting the Report.

When selected, a Flow Total Report dialog box will appear. This dialog box allows the user to select:

1…From and To Date Times

Sets limits on the Total Time period of the Report

From and To Date Times will default to the Start and End of the current dataset

2…The type of report required

Hourly (Total Volumes for each Hour)

Daily (Total Volumes for each Day)

Weekly (Total Volumes for each Week)

Monthly (Total Volumes for each Month)

3…The Logger Channel to be used for the report

The required Flow Channel should be selected

4…The Flow Time Period of the logged data

per Second

per Minute

per Hour

(eg if your flow rate is Litres per minute this should be set to per Minute, if your flow rate is Gallons per Hour this should be set to per Hour)

5…The Volume Units of the logger data

Enter the text you require on the report to describe the Volume Units

(eg if your flow rate is Litres per minute enter Litre or lt, if your flow rate is Gallons per Hour enter Gallon or Gal)

6…Preview

This button allows the user to preview the report

7…Print

This button prints the report

8… Cancel

This button closes the Flow Total Report module and returns the user to the Omnilog Main Screen

The Flow Total Report dialog box will remember most of the last options selected by a user and present these as the default options the next time the dialog box is used. The dialog box will not remember the Logger Channel to be used as this could change from logger to logger. The required Flow Channel will need to be selected each time the Flow Total Report dialog box is used.

Reinstalling New Versions of the Omnilog Data Management Program will not effect the Flow Total Report.